2018年11月30日星期五

Common faults and solutions for CNC machine tool spindles IV

The cause of the failure and the solution:
1. System output pulse time is not enough: adjust the system's M code output time.
2. The inverter is in jog state: Refer to the instruction manual of the inverter and set the parameters.
3. The control components of the spindle line are damaged: check whether the contacts on the circuit are in good contact, check whether the DC relay is damaged which caused the contact can not self-lock. 
4. The spindle motor is short-circuited, causing thermal relay protection: find the cause of the short circuit and reset the thermal relay.
5. The spindle control loop does not have self-locking circuit, and the parameter is set to pulse signal output, so that the spindle can not operate normally: change the start and stop parameters of the system control spindle to the level control mode.
Problem six: the spindle rotation can not stop
The cause of the failure and the solution:
1. AC contactor or DC relay is damaged and uncontrollable: replace AC contactor or DC relay.